Journal of Clinical Epidemiology
Volume 55, Issue 4 , Pages 338-344, April 2002

Accuracy of blood pressure measurement and anthropometry among volunteer observers in a large community survey

  • Claire Adams

      Affiliations

    • University of Western Australia, School of Dentistry, 35 Stirling Hwy, Crawley, WA 6009, Australia
    • Corresponding Author InformationCorresponding author. Tel.: +1-61-8-9380-8181; fax: +1-61-8-9380-1199 E-mail address:(C. Adams)
  • ,
  • Valerie Burke

      Affiliations

    • University Department of Medicine, University of Western Australia, Royal Perth Hospital, GPO Box X2213, Perth, WA 6001, Australia
  • ,
  • Lawrie J Beilin

      Affiliations

    • University Department of Medicine, University of Western Australia, Royal Perth Hospital, GPO Box X2213, Perth, WA 6001, Australia

Received 14 February 2001; received in revised form 5 October 2001; accepted 8 October 2001.

Abstract 

The Busselton Survey is a population survey that is held about every three years. In 1994–1995 a re-survey was held of all past participants and 8,502 attended. Financial constraints precluded employing staff for data collection for blood pressure and anthropometry, these therefore were collected by unpaid lay volunteers. Quality control by a health professional was critical to the assessment and maintenance of accuracy in these measurements. For blood pressure three readings were taken simultaneously by a quality control person and the volunteer using a dual stethoscope. Duplicate anthropometric measurements were taken by a criterion anthropometrist and the volunteer. Inter and intra-observer technical errors of measurement (TEM) were calculated. Sixty-two volunteers were trained to take BP measurements; of these, 38 collected data, and 63 were trained in anthropometry; of these, 30 were suitable as measurers. Training was conducted on a group and individual basis by the quality assurance person for the study both in the Perth metropolitan area and rural Busselton. The TEM for SBP was 1.6 mm Hg (SD 1.0 mm Hg) and 1.5 mm Hg (SD 0.8) for DBP. For skin-folds intra-observer TEM ranged from 0.6 mm to 1.0 mm. Between-observer TEM ranged from 2.1 mm to 5.4 mm. For limb and waist circumferences, intra-observer TEM ranged from 0.3 cm to 1.6 cm. Between-observer TEM for circumferences ranged from 0.5 cm to 1.9 cm. Unpaid volunteer measurers can, if carefully trained and supervised, provide acceptable blood pressure data and anthropometry in large population surveys.

Keywords:  Technical errors of measurement, Blood pressure, Anthropometry, Quality control, Volunteers, Busselton

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0895-4356(01)00492-9

Journal of Clinical Epidemiology
Volume 55, Issue 4 , Pages 338-344, April 2002